Thoreau Center

时间:2007-04-20 15:44:10 作者:未知 来源:筑能网

 

 

地址: San Francisco, CA

建筑面积: 6,780 sq. meters

竣工日期: April 1996

高度: 2-story buildings

能源利用: Although the Thoreau Center does not set any records for low energy use, it does demonstrate that a historic rehabilitation with a low budget can successfully integrate energy-conserving measures and greatly reduce the energy usage of the buildings, resulting in substantial energy savings per year.

Electrical use, in particular lighting use, is by far the most important component for energy efficiency in the San Francisco Bay Area, due to the mild climate. Fluorescent uplighting was selected for both energy efficiency and good quality of light, especially in areas of high computer use.

Lighting controls are ordinary light switches combined with occupancy sensors in many areas to assure energy savings, particularly in intermittently used rooms.

The energy performance of the project was modeled using DOE-2. Natural gas consumption has been lower than predicted; however, electricity consumption has been significantly higher than projected in each of the four buildings.

Assuming the problem is not something relatively simple like incorrect billing, we can only speculate about the possible reasons. First, the lack of daylight controls on the electric lighting may mean that the energy savings from the superb daylighting strategies are not being realized (if, for example, the lights don't get turned off). Second, the impact of air conditioners in three of the buildings may be significantly greater than expected. Third, there may be significantly higher plug loads in the offices than was modeled. And fourth, the electricity consumption associated with the HVAC equipment might be significantly higher than expected.

At the owner's request, the project uses tried-and-true technology with low initial cost and fast payback. Due to the climate, site, and historic nature of the building, the use of operable windows and natural ventilation was strongly supported and implemented.

节水方案: Low-flow plumbing fixtures were specified and installed because they conserve water as well as reduce distribution pumping energy and lower domestic hot water heating energy.

Site elements that were integrated into the design for water conservation include: introduction of drought-tolerant plants, use of low-flow irrigation systems, and capture of rainwater for supplemental irrigation.

Excavation and use of historic drainage structures minimize runoff.

材料选择: From the initial stages of the design process, Lynn Simon, of Simon and Associates, provided design review, research, and input for selection of materials and systems to assure environmental performance. This process led the design team to a series of informed choices based upon environmental criteria and real-world issues including project schedule, budget, available resources, and aesthetics.

The material selections have environmental and health merits that traditional materials have typically not considered. The production and use of these materials, which are generally less toxic for both the planet and its occupants, means less energy consumption as well as less natural resource depletion and pollution. The selection of green building materials began with preliminary criteria, considering all phases of each product's life cycle.

Manufacturers who had established credentials as environmentally concerned companies or as having products with some environmental or health benefits were selected and their products researched. Environmental product guidelines based on the preliminary criteria were then used to evaluate each product. In addition, product brochures and Material Safety Data Sheets (MSDS) were requested and evaluated.

室内环境品质: The Thoreau Center was initially viewed as a good opportunity to consider natural ventilation in lieu of mechanical cooling. Located near the Pacific Ocean, the site has a very temperate climate that only infrequently exceeds 80 degrees F. The building geometry further encouraged natural ventilation because of the shallow floor plates that place occupants within close proximity of a window. The knowledge of historical building performance and occupant comfort supported the decision to use operable windows and natural ventilation.

Occupant Lighting

The primary goal for the lighting design of the Thoreau Center was to minimize energy use while providing a pleasant quality of light. David Malman, of Architectural Lighting Design, designed the lighting to be very comfortable for the users to whom fluorescent lighting had a bad connotation. Fluorescent uplighting was selected because of its soft, shadow-free, low-glare quality of light, particularly good where there is high computer use. Some fixtures also emit a small quantity of downlight, which adds visual interest and increases fixture efficiency.

The lighting consultant prepared computer calculations to plot out the lighting levels in the work spaces to assure that these levels would be adequate. Light levels in two offices range from 15 to 45 footcandles, and the connected power density is 1.06 W/ft2 (11.4 W/m2).

新闻订阅】 【打印】 【网站论坛】 【字体: 】 【发表评论】 【关闭
共有 人对本文发表评论   [查看所有评论]
昵称:
申请加精
相关文章

最新资讯
·北京海淀启动既有建筑节能改造 环保抗震双管齐下
·重庆:新建公共建筑 将避开东西向日晒
·《绿色建筑装饰装修工程》 奥运推动绿色装修产业
·北京:建设部出新规 住宅节能信息写入买房合同
·看重建筑节能示范效应
·中国光伏产业欲拓展国际市场 前景面临诸多挑战
·中新生态城总体规划公示结束 强化七方面建设
·建设部力推建筑节能
·城市化建设呼唤绿色建筑 开发商应当尽早行动
·建筑需要成为城市的基础而非城市榨汁机
 
下载排行
·《ANSYS工程结构实例分析》
·《建筑设计作品博览 国外建筑竞赛优秀作品精粹
·《大学生建筑设计优秀作品集》
·《室内设计基础》
·《节能技术实用全书》(上卷)
·《光与建筑》
·《建筑力学与建筑结构》
·《家居装修精选方案》
·《钢结构设计原理》
·《百年建筑:天人合一 馆人合一》
 
行业新闻
热点专题

中国既有建筑节能改造之路

电器能效标识进行时

携手能源世界共助震区灾民

公共建筑节能降耗启示录
政策分析
行业人物
郑时龄
孟宪淦:破解太阳能与建筑两张皮
最新论文
最新书籍

《大气污染控制工程》

《大气环境模式计算方法》

《城市中小型污水处理厂的建设与管理》

《城市污水处理厂的建设与管理》
最新图纸
最新资料
招标信息
论坛精华


住房和城乡建设部科技与发展促进中心(CSTCMOC) 中国绿色建筑委员会(CHINAGBC) 国际智能、绿色建筑与建筑节能大会(IGEBC) 指定合作网站
承办:沃德高科(北京)科技有限公司
Copyright ©2007-2008 CHINAGB.NET.All Rights Reserved.   京ICP备07024683号
通信地址:住房和城乡建设部北附楼312室(100835)
联系信箱:nengyuanshijie163.com  传真电话:010-88585380
合作热线:010-88585610/11/12转810/809/808/  QQ:396630266 304586884  MSN:lian572hotmail.com  

关于我们 - 联系我们 - 广告服务 - 友情链接 - 网站导航