Eastern Village

时间:2007-04-16 17:16:52 作者:未知 来源:筑能网

 

地址: Silver Spring, MD 

建筑面积: 8,600 sq. meters

竣工日期: November 2004

能源利用: The EVC building is a four-story, multifamily, residential building that was converted from a U-shaped concrete-framed office building. The renovated building maintains the same U-shape design, but includes added green features, including a front façade with a sunshade and a “living” roof with plants to control rainwater runoff and reduce cooling loads.

Each of the dwelling units, along with common areas of the building, is served with high-efficiency ground-source heat pumps connected to a common circulation loop. The circulation loop utilizes a U-tube ground heat exchanger in order to provide heat rejection for the heat pumps in cooling mode and heat addition for the heat pumps in heating mode. The ground heat exchanger consists of 40 boreholes, each six inches in diameter and 600 feet deep, in which 1-¼“ polyethylene U-tube pipes are installed.

Wall insulation was added as part of the retrofit, and new windows use low-emissivity glazing for an improved building envelope. The roof has an R value of 23.6 at the green roof and 25 at the pavers. Interior lighting consists of a combination of compact fluorescent fixtures and standard incandescent fixtures, and exterior lighting is designed to be appropriately low-level. Energy Star(r) appliances throughout reduce the building's plug load.

The retrofitted EVC building performs 44% better than the ASHRAE 90.1-1999 baseline requirement using the energy cost budget methodology.

节水方案: Native and adaptive species of plants are used in the courtyard garden and vegetative roof, eliminating the need for a permanent irrigation system. The selected plants are all native to Maryland and after the first year of establishment will not require irrigation. Four rain barrels have also been acquired for future connection to the building's existing downspouts; collected rainwater will be used in extreme drought conditions and future vegetable gardening.

Dwelling units and common spaces have low-flow plumbing fixtures meeting or providing higher efficiency than 1992 Energy Policy Act standards, as well as closets with hookups for optional stacked washers and dryers. The interior plumbing fixtures use 20% less water than conventional condominium buildings as a result of a combination of ultra-water-efficient showerheads (using 1.75 gallons per minute) and low-flow lavatory faucet aerators (using 1.5 gallons per minute). Energy Star(r), low-water-use dishwashers and clothes washers also save 35% compared with standard appliances.

材料选择: The adaptive reuse of the existing building preserved over 96% of the existing structure and over 82% of the existing shell, not including windows, conserving significant quantities of material and related resources.

New materials used for the project include products manufactured with recycled content, such as rubber surfacing, metal trellising, structural steel, steel studs, insulation, roofing, gypsum board, carpet, and carpet pad. Furthermore, linoleum and bamboo flooring, both made from rapidly renewable materials, were used in sufficient quantities to represent over 6% of the total new materials cost. Finally, regionally manufactured materials were used where practical, conserving transportation resources.

室内环境品质: Though some smaller window openings were retained form the existing structure, new window openings and double-height spaces were carved out of selected floor slabs. These strategies, combined with light-colored interior finishes, enhance daylighting to the extent practical.

A recessed floor grate placed at the main building entrance traps particulates before they enter the building, and an abundance of hardsurface flooring in common spaces and some units facilitates easier, more effective cleaning than carpeting would allow. The volatile organic compound (VOC) content of adhesives and sealants used in the project comply with the limits of South Coast Air Quality Management District (SCAQMD) Rule 1168. Zero-VOC and low-VOC paints meeting the VOC and chemical component limits of Green Seal’s Standard GS-11 were also used. Carpet systems, where used, comply with the Carpet and Rug Institute's Green Label Indoor Air Quality Test Program.

The retrofitted building meets the minimum requirements of voluntary consensus standard ASHRAE 62-1999, Ventilation for Acceptable Indoor Air Quality and approved addenda, with operable windows, exhaust fans, and an optimum average infiltration of approximately 0.35 air changes per hour. Pathways for environmental tobacco smoke transfer between individual residential units were minimized by sealing penetrations in walls, ceilings, and floors in the residential units and by sealing vertical chases adjacent to the units. In addition, all doors in the residential units leading to common hallways are weather-stripped to minimize air leakage into the hallway. Blower-door testing performed on a 10-unit sampling verified that environmental tobacco smoke transfer from private units would be sufficiently controlled by the building design and construction.

新闻订阅】 【打印】 【网站论坛】 【字体: 】 【发表评论】 【关闭
共有 人对本文发表评论   [查看所有评论]
昵称:  验证码: 看不请,请单击图片!
申请加精
相关文章

最新资讯
·冬季储冰用于夏季空调 科技奥运谱写绿色诗篇
·成就水立方膜结构 氟涂料为奥运添彩
·“绿色制造关键技术与装备”重大项目专家组成立
·推广绿色建材 江苏立法禁止生产粘土实心砖
·绿色奥运 能源危机 混合动力日渐“亲民”
·北京:新建住宅门窗 隔音将有规可依
·绿色建筑呼之欲出 高能耗下的写字楼如何发展
·郑州:新建用房不装太阳能节能系统将不验收
·南希·萨默维尔:用绿色美化我们的屋顶
·两个月的限行还能留给北京什么
 
下载排行
·《ANSYS工程结构实例分析》
·《建筑设计作品博览 国外建筑竞赛优秀作品精粹
·《大学生建筑设计优秀作品集》
·《室内设计基础》
·《节能技术实用全书》(上卷)
·《光与建筑》
·《建筑力学与建筑结构》
·《家居装修精选方案》
·《钢结构设计原理》
·《百年建筑:天人合一 馆人合一》
 
行业新闻
热点专题

奥运来了,看看谁家更节能

中国既有建筑节能改造之路

电器能效标识进行时

携手能源世界共助震区灾民
政策分析
行业人物
郑时龄
孟宪淦:破解太阳能与建筑两张皮
最新论文
最新书籍

《大气污染控制工程》

《大气环境模式计算方法》

《城市中小型污水处理厂的建设与管理》

《城市污水处理厂的建设与管理》
最新图纸
最新资料
招标信息
论坛精华


住房和城乡建设部科技与发展促进中心(CSTCMOC) 中国绿色建筑委员会(CHINAGBC) 国际智能、绿色建筑与建筑节能大会(IGEBC) 指定合作网站
承办:沃德高科(北京)科技有限公司
Copyright ©2007-2008 CHINAGB.NET.All Rights Reserved.   京ICP备07024683号
通信地址:住房和城乡建设部北附楼312室(100835)
联系信箱:nengyuanshijie163.com  传真电话:010-88585380
合作热线:010-88585610/11/12转810/809/808/  QQ:396630266 304586884  MSN:lian572hotmail.com  

关于我们 - 联系我们 - 广告服务 - 友情链接 - 网站导航