个人简介 |
英:Since 1990 I am engaged professionally in the test and research work of construction fireproof. I undertook many construction fireproof safety research items from the Ministry of Construction, Ministry of Science and Technology, Ministry of Public Security and National Natural Science Fund. I participated in the establishment and revision of a number of national and industry standards for construction fireproof. In recent years, I do a lot of experimental studies in the fireproof safety of exterior wall external thermal insulation. |
|
演讲摘要 |
英:Under the current technique level, adopt the valid structural combination manner for element or component in external wall insulation systems with rigid polystyrene or polyurethane foam, is a practical way to raises fire safety class of buildings. The wall corner or window model fire test, is a full scale test, can be imitating actual fire status and assessing the ability of external insulation systems to resist external fire. The Cone Calorimeter test, is a small scale fire test, can be used for the normal examination of the external wall insulation engineering construction. |